How to read a cable datasheet: the five numbers that decide a job
A datasheet is a promise you can enforce
Most cable disputes are not about copper quality. They are about a number nobody wrote down. The datasheet exists so that the purchase order can say "meets the stated limits" and a test report can be compared against a figure instead of an opinion.
Here is what each of the five numbers on a structured cabling datasheet actually constrains, using the limits we publish for our own range.
1. Characteristic impedance: 100 ± 15 ohm
Impedance is the ratio of voltage to current for a wave travelling down the cable. It is set by the geometry — conductor diameter, insulation wall, pair spacing — not by the copper purity. The tolerance band matters more than the centre value: 100 ± 15 ohm accepts 85 to 115 ohm.
Why it is a purchasing criterion: a channel built from cable at one end of the band and connectors at the other produces reflections at every transition. The link may pass continuity and still fail a certifier sweep, and the installer will blame the reel.
In this range the 100 ± 15 ohm limit is stated for the network, multi-pair and patch cord families. The coaxial range is a different animal — 75 ohm, matched to video equipment rather than to Ethernet.
2. Conductor resistance: ≤ 9.38 ohm per 100 m at 20 °C
This is DC resistance, and it is the number that decides whether the cable will run Power over Ethernet at distance. Resistance rises with temperature, so a limit quoted at 20 °C is a colder-day best case; in a hot ceiling void the same conductor is measurably worse.
9.38 ohm per 100 m converts to roughly 23 AWG-equivalent behaviour. If a customer is pushing PoE++ over 90 m, ask for the conductor size before quoting the reel — a 0.50 mm conductor and a 0.57 mm conductor are both "CAT6" and behave differently under load.
3. Mutual capacitance: ≤ 5.6 nF per 100 m
Capacitance between the two conductors of a pair, measured per unit length. It is the second half of the impedance story: too much capacitance and the pair behaves like a low-pass filter, which shows up as return loss and eventually as a link that trains down to a lower speed.
Our network cable limit is 5.6 nF/100 m, and the multi-pair telephone range is looser at 6.6 nF/100 m because it is not carrying Ethernet.
4. Insulation resistance: ≥ 5000 MΩ·km
A leakage figure. It is quoted in megohm-kilometres because insulation resistance scales with length — the longer the cable, the lower the measured value for the same compound. A factory measuring a 500 m reel and one measuring 100 m are not comparing the same number unless they normalise.
A failing insulation resistance reading usually means moisture or a damaged jacket, not a bad compound. It is the first test to run when a reel has been stored in a humid yard.
5. The test standard, not the marketing category
A category on the box is a claim; the standard is the method. Our range lists UL758, UL1581, UL444, TIA/EIA-568, CSA C22.2, ISO/IEC 11801, YD/T1019-2001, GY/T135-1998 and SJ/T11138-1997 across the range — different markets, different acceptance tests, and a customer in one market may not accept evidence produced under another.
When you quote, ask which standard the acceptance test will follow. That single question prevents the common end-of-job argument about whether a 100 MHz sweep or a 500 MHz sweep was the agreed proof.
What a datasheet cannot tell you
Conductor size in AWG is not published for this part number; it is stated as a diameter in millimetres. If the customer's specification is written in AWG, convert before quoting rather than assuming the nearest size matches.
And no datasheet tells you the installation quality. A cable inside its limits, pulled round a tight corner, is out of limits at the far end. The numbers are a floor, not a guarantee.
Frequently asked
Which number should go into the purchase order?
Impedance and conductor resistance first: they cover both signal integrity and PoE. Add the test standard and the acceptance method — those two prevent the argument at handover.
Is a lower conductor resistance always better?
For the same diameter, yes. Across diameters, a thicker conductor has lower resistance but also changes the impedance unless the insulation is adjusted, so compare full constructions rather than single figures.
Do these limits apply to patch cords too?
The specification states the same 100 ± 15 ohm and 9.38 ohm/100 m limits for the patch cord family, which is why we recommend buying cords from the same production as the cable.
Where can I see the test limits on this site?
The factory page lists the test limits per stage, and each product page repeats the electrical block that applies to its family.
Need the actual part numbers?
The product pages carry the full specification for every item.